Grid-connected Testing of Renewable Energy Power station

Home > Our Services > Testing Services > Electronic and Electrical > Outfield Testing > Grid-connected Testing of Renewable Energy Power station

Service Description

In recent years, renewable energy power generation has developed rapidly in China. However, renewable energy resources represented by wind energy and solar energy are random, volatile, and intermittent, and are affected by their power generation equipment. Large-scale renewable energy generation and grid connection will have certain impacts on some areas of power system and sometimes even the entire system. The renewable energy grid-connected technology is a key technology to solve the renewable energy development problems. Therefore, on-site grid-connected testing of renewable energy power station is of great importance.

Ti Balun is committed to the testing activities related to renewable energy power station acceptance and grid-connected performance, and has the corresponding technical capabilities and experience.

Main ability Arranged with mobile detection platforms for photovoltaic power station/energy storage power station with a capacity of 2.5MW and below;
Possess the ability to carry out on-site testing of the grid connection performance of medium and high voltage grid connection and low voltage connection to the distribution network;
Possess the ability to test the power quality and regulate the power of photovoltaic/energy storage power generation units, low/high voltage ride-through, low-high voltage consecutive ride-through, grid adaptability, and power station characteristic capability.
Main Standard
Grid-connected Testing Main standards
Photovoltaic power station GB/T 19964, GB/T 31365, NB/T 32026
Energy storage power station GB/T 36547, GB/T 36548
Wind power farm GB/T 19963, NB/T 31078, NB/T 31051, GB/T 36995 and other standards
Main Items
Active power Test the maximum rate of change of active power during normal startup, shutdown, and solar irradiance growth, the maximum deviation and response time of active power setting control.
Reactive power Test the operating range of power factor, and adjust the speed of reactive power during voltage command control.
Power grid adaptability Test the voltage deviation, flicker, harmonics, inter-harmonics and frequency adaptability, three-phase voltage imbalance adaptability, etc.
Power quality Test indicators such as flicker value, harmonic and inter-harmonic values caused by access to public connection points.
Fault ride-through Test the overall fault ride-through characteristics of the power station.