Performance Evaluation Testing of renewable Energy Station

Home > Our Services > Testing Services > Electronic and Electrical > Outfield Testing > Performance Evaluation Testing of renewable Energy Station

Service Description

With the sustainable demand for energy development, China's renewable energy power generation industry is developing rapidly. A large number of large-scale renewable energy generating stations represented by wind and solar have emerged. As a large power generation system, the performance of a renewable energy station will directly affect the quality and efficiency of power generation, as well as the impact on the entire grid when it is later connected to the grid. The performance evaluation of a renewable energy station is an important link of its construction and acceptance.
Ti BALUN is committed to the testing activities related to renewable energy power station acceptance and grid-connected performance, and has the corresponding technical capabilities and experience.

Main ability Critical equipment (photovoltaic modules and inverters) test
PV string test
Photovoltaic array test
Photovoltaic subsystem test
PV system overall test
Main Standard

CGC/GF 003.1, CNCA/CTS 0004 etc.

Main Items
Type Test items
Photovoltaic module infrared thermal imaging (IR) test detect abnormal temperature changes of operating modules on site.
Photovoltaic module electroluminescence (EL) test test defects such as cracks, hidden cracks, chipping, cracks, broken grids, short circuits, poor printing, and process pollution in the cells inside the modules.
Photovoltaic module I-V test verify the I-V characteristics of the module in the actual operating environment to find the defects and problems of the module.
Photovoltaic inverter conversion efficiency calculate the impact of the electrical conversion efficiency of the inverter in the comprehensive efficiency of the photovoltaic system.
Photovoltaic inverter output power quality verify the voltage deviation, voltage fluctuation and flicker value, harmonic current, interharmonic, voltage unbalance, DC current component, and power factor on the output side.
Photovoltaic string I-V test verify the consistency of performance between strings, the loss of strings in series, and the loss of strings in parallel.
Photovoltaic square array performance index reflect the heating, mismatch, pollution loss and others of photovoltaic module diodes, wires, modules, etc. during the test period.
Photovoltaic array performance grounding test the connection reliability of the protection device or the connection body, and the ground connection shall not be loose or incompletely contacted.
Photovoltaic square array performance insulation verify the safety performance of the array insulation.
Photovoltaic system performance index the comprehensive impact of the photovoltaic array due to the temperature of the array, incomplete utilization of radiation, failure of system components causing the loss of the rated output of the array.
Evaluation Site of Ti BALUN

Equipped with a UAV thermal imaging system, which can quickly and effectively test abnormal hot spots, greatly improving the testing efficiency;

Equipped with a portable PR value automatic acquisition system, which can effectively collect irradiance, cumulative irradiance, temperature and humidity data in real time and automatically save and transmit the data.

Ti BALUN Project References

Performance evaluation of CGN Hebei Chengde photovoltaic power station;

Performance evaluation of CGN Yunnan Yinyuan photovoltaic power station;

Performance evaluation of the Three Gorges Ningxia Lingwu photovoltaic power station;

Performance evaluation of Ningxia Wuzhong Photovoltaic Power Station in the Three Gorges Project;

Performance evaluation of CGN's Inner Mongolia Sunshine PV Power Plant;

Performance evaluation of CGN's Inner Mongolia Shangdu photovoltaic power station;

Performance evaluation of Loudi photovoltaic poverty alleviation power station;

Performance evaluation of Hanchuan Mahe photovoltaic poverty alleviation power station;

Performance evaluation of Huaneng Golmud photovoltaic power station;

Performance evaluation of CGN Xitieshan photovoltaic power station;

Performance evaluation of Jiashan Fengling photovoltaic power station;

Performance evaluation of Hexin precision photovoltaic power station;

Online Service Consultation
  • 0/1000
Submit

1.When you provide personal information to this website, we will not disclose (share, sell or reveal) any of your personal information to third parties (including companies or individuals) without your permission, except as mandated by law or government.
2.The information you provide will only be used to help us provide you with better services.

Your message has been received
Our staff will contact you as soon as possible

Return